ET II Specific - Set 1
Rating
0
0
There are no comments for now.
1.
In an ASME Section V Article 8 style bobbin reference standard, the flat-bottom holes of 80%, 60%, 40% and 20% wall depth are drilled from the:
2.
During bobbin probe setup, the phase is commonly rotated so that the through-wall hole signal sits at about 40°. What is this convention for?
3.
Relative to the through-wall reference, a shallow ID-initiated flaw on a differential bobbin channel typically rotates:
4.
Why is a simulated support ring often fitted to the tube reference standard?
5.
What is the main purpose of a tubesheet map in a heat exchanger eddy current report?
6.
A bobbin indication is sized at 45% through-wall. The owner's plugging limit in this example is 40%. What should the Level II do?
7.
A dent stops the normal bobbin probe, so a smaller-diameter probe is used for those tubes. What must be done?
8.
A tube cannot be examined full length because of a restriction. The report should:
9.
Why should the bobbin probe be pulled at the same speed during examination as during standardization?
10.
An illustrative phase-to-depth curve reads: 100% = 40°, 80% = 60°, 60% = 85°, 40% = 110°, 20% = 150°. An OD pit at 130° is approximately:
11.
On a surface notch reference block, why are several EDM notch depths (for example 0.2, 0.5 and 1.0 mm) provided?
12.
When setting up a pencil probe on a notch block, which step normally comes first after choosing the probe and frequency?
13.
A surface probe has an effective coverage width of 4 mm and the procedure requires 50% overlap. The maximum scan index is:
14.
Fatigue cracks are expected to grow radially from fastener holes in an aluminum skin. A suitable surface-probe scan is:
15.
A rotating bolt-hole probe has an effective coil width of 1.0 mm and turns at 600 rpm. What is the maximum forward speed for full coverage?
16.
Before a bolt-hole eddy current examination, the hole should be:
17.
In conductivity measurement per ASTM E1004, the instrument is standardized using:
18.
Conductivity is measured on aluminum sheet thinner than about three standard depths at the instrument frequency. The reading will typically be:
19.
ASTM E376 covers measuring nonconductive coating thickness on a non-magnetic metal substrate. The instrument should be standardized with: